OFFICE OF THE ENGINEER-IN-CHIEF, PWD.,
MIZORAM : AIZAWL.

 

CIRCULAR

The following plinth area rates of various buildings (for Northern Mizoram) will be applicable from 1st July 2003 with specifications mentioned below :-Northern Mizoram covers Aizawl, Champhai, Kolasib, Mamit and Serchhip districts.

A Type of buildings Plinth area rates
  REINFORCED CONCRETE BUILDING :  
1 Ground Floor Rs.    6,993.00 per sqm
2 First Floor and subsequent floors Rs.   5,172.00 per sqm.
3 Top floor ( Rcc flat roof ) Rs.    6,376.00 per sqm
4 Top floor ( Rcc slope roof ) Rs.    6,629.00 per sqm
B SEMI PERMANENT BUILDING : Rs.    6,492.00 per sqm.
C ASSAM TYPE BUILDING : Rs.    4,917.00 per sqm.

A  :  SPECIFICATIONS  FOR  RCC  BUILDING

  1. Earthwork shall be in ordinary soil or hard soil.
  2. Cement concrete 1:3:6 for foundation bed 10cm thick.
  3. All Rcc works shall be of proportion 1:2:4 (minimum strength of M15).
  4. Reinforcement steel shall be of HYSD bars (Fe - 415).
  5. All centering and shuttering shall be of timber.
  6. Plinth masonry shall be of C/R masonry 0.25m thick in cement mortar 1:6.
  7. Ground flooring shall consist of layers (a) Stone aggregate 90mm nominal size 10cm thick, (b) Plain cement concret 1:4:8, 7.5cm thick, (c) Plain cement concrete 1:2:4, 4cm thick with a floating coat of neat cement.

  8. Flooring in all the floors other than ground floor shall be of plain cement concrete 1:2:4, 2.5cm thick with a floating coat of neat cement.
  9. Toilet flooring shall be 40mm thick marble chips.
  10. Toilet wall shall be white glazed tiles for 1.5m height.
  11. All wood work shall be of 1st class local wood.
  12. All half brick work shall be of 1st class brick in cement mortar 1:4.
  13. Exposed surfaces of Rcc shall be smooth finished with cement plaster 12mm thick in cement mortar 1:3 (1cement : 3fine sand).

  14. Ceiling plaster shall be of 12mm thick in cement mortar 1:3 (1cement : 3fine sand).
  15. External wall plaster shall be of 20mm thick in cement mortar 1:4 (1cement : 4fine sand).
  16. Internal wall plaster shall be of 12mm thick in cement mortar 1:4 (1cement : 4fine sand).
  17. Dado of appropriate height shall be provided.
  18. External walls shall be painted with water proofing cement paint.
  19. Internal walls shall be painted with acrylic distemper over distemper primer.
  20. All wood works shall be painted with synthetic enamel paint over wood primer.
  21. Hand railing or parapet wall shall be provided all round for flat roof.
  22. Appropriate roof treatment shall be provided for flat roof and slope roof.

 