CIRCULAR

         The following plinth area rates of various buildings (for Northern Mizoram) will be applicable from 1st July 2003 with specifications mentioned below :-

Northern Mizoram covers Aizawl, Champhai, Kolasib, Mamit and Serchhip districts.

Type of buildings Plinth area rates
A REINFORCED CONCRETE BUILDING :    
1 Ground Floor  Rs.  6,993.00 per sqm.
2 First Floor and subsequent floors  Rs.  5,172.00 per sqm.
3 Top floor ( Rcc flat roof )  Rs.  6,376.00 per sqm.
4 Top floor ( Rcc slope roof )  Rs.  6,629.00 per sqm.
B SEMI PERMANENT BUILDING :  Rs.  6,492.00 per sqm.
C ASSAM TYPE BUILDING :  Rs.  4,917.00 per sqm.

 

Separate provisions are made on the above plinth area rates for the following :-
1 Site Development @ 5.00% for all type
2 Sanitary and water supply @ 7.50% for all type
3 Internal Electrification :      
(a) Assam type building @ 5.00%  
(b) Semi permanent building @ 8.00%  
(c) R.C.C building @ 15.00%  
4 Work charged establishment @ 2.00%  
5 Contingency charge @ 3.00%  
6 Agency charge @ 11.75%  

A  :  SPECIFICATIONS  FOR  RCC  BUILDING

1 Earthwork shall be in ordinary soil or hard soil.
2 Cement concrete 1:3:6 for foundation bed 10cm thick.
3 All Rcc works shall be of proportion 1:2:4 (minimum strength of M15).
4 Reinforcement steel shall be of HYSD bars (Fe - 415).
5 All centering and shuttering shall be of timber.
6 Plinth masonry shall be of C/R masonry 0.25m thick in cement mortar 1:6.
7 Ground flooring shall consist of layers (a) Stone aggregate 90mm nominal size 10cm thick, (b) Plain cement concret 1:4:8, 7.5cm thick, (c) Plain cement concrete 1:2:4, 4cm thick with a floating coat of neat cement.
8 Flooring in all the floors other than ground floor shall be of plain cement concrete 1:2:4, 2.5cm thick with a floating coat of neat cement.
9 Toilet flooring shall be 40mm thick marble chips.
10 Toilet wall shall be white glazed tiles for 1.5m height.
11 All wood work shall be of 1st class local wood.
12 All half brick work shall be of 1st class brick in cement mortar 1:4.
13 Exposed surfaces of Rcc shall be smooth finished with cement plaster 12mm thick in cement mortar 1:3 (1cement : 3fine sand).
14 Ceiling plaster shall be of 12mm thick in cement mortar 1:3 (1cement : 3fine sand).
15 External wall plaster shall be of 20mm thick in cement mortar 1:4 (1cement : 4fine sand).
16 Internal wall plaster shall be of 12mm thick in cement mortar 1:4 (1cement : 4fine sand).
17 Dado of appropriate height shall be provided.
18 External walls shall be painted with water proofing cement paint.
19 Internal walls shall be painted with acrylic distemper over distemper primer.
20 All wood works shall be painted with synthetic enamel paint over wood primer.
21 Hand railing or parapet wall shall be provided all round for flat roof.
22 Appopriate roof treatment shall be provided for flat roof and slope roof.

B  :  SPECIFICATIONS  FOR  SEMI  PERMANENT  BUILDING

1 Earthwork shall be in ordinary soil or hard soil.
2 All posts shall be of Rcc 20cm x 20cm with normal foundation footing.
3 All Rcc works shall be of proportion 1:2:4 (minimum strength of M15).
4 Reinforcement steel shall be of HYSD bars (Fe - 415).
5 All centering and shuttering shall be of timber.
6 Plinth masonry shall be of C/R masonry 0.25m thick in cement mortar 1:6.
7 Ground flooring shall consist of layers (a) Stone aggregate 90mm nominal size 10cm thick, (b) Plain cement concret 1:4:8, 7.5cm thick, (c) Plain cement concrete 1:2:4, 4cm thick with a floating coat of neat cement.
8 Toilet flooring shall be 40mm thick marble chips.
9 Toilet wall shall be white glazed tiles for 1.5m height.
10 All wood work shall be of 1st class local wood except ceiling frame.
11 All walls shall be half brick work with 1st class brick in cement mortar 1:4.
12 Exposed surfaces of Rcc shall be smooth finished with cement plaster 12mm thick in cement mortar 1:3 (1cement : 3fine sand).
13 Ceiling shall be of 4mm thick AC sheet over 2nd class local wood frame work.
14 External wall plaster shall be of 20mm thick in cement mortar 1:4 (1cement : 4fine sand).
15 Internal wall plaster shall be of 12mm thick in cement mortar 1:4 (1cement : 4fine sand).
16 Roofing shall be of 0.63mm thick GCI sheet over 1st class timber truss.
17 External walls shall be painted with water proofing cement paint.
18 Internal walls shall be painted with acrylic distemper over distemper primer.
19 All exposed wood works shall be painted with synthetic enamel paint over wood primer.
20 GCI roof shall be painted with antifungus roof paint over primer.

C  :  SPECIFICATIONS  FOR  ASSAM  TYPE  BUILDING

1 Earthwork shall be in ordinary soil or hard soil.
2 All posts shall be of 1st class timber fixed with iron clamps on concrete pillars with normal foundation footing.
3 Plinth masonry shall be of C/R masonry 0.25m thick in cement mortar 1:6.
4 Ground flooring shall consist of layers (a) Stone aggregate 90mm nominal size 10cm thick, (b) Plain cement concret 1:4:8, 7.5cm thick, (c) Plain cement concrete 1:2:4, 4cm thick with a floating coat of neat cement.
5 Toilet flooring shall be 40mm thick marble chips.
6 Toilet wall shall be white glazed tiles for 1.5m height.
7 All wood work shall be of 1st class local wood except ceiling frame.
8 Walls shall be of 5mm thick AC plain sheet.
9 Ceiling shall be of 4mm thick AC plain sheet on 2nd class local wood frame work.
10 Roofing shall be of 0.63mm thick GCI sheet over 1st class timber truss.
11 Internal walls shall be painted with acrylic distemper over distemper primer.
12 Door & window frames shall be painted with synthetic enamel paint over wood primer.
13 GCI roof shall be painted with antifungus roof paint over primer.

 

Ramhluna Khiangte
 Engineer in Chief, PWD
Mizoram

  Memo No.EC/D&R/SOR/2000/74    :    Dated Aizawl the 14th July 2003,
  Copy to:-
 
1 P.S to Hon’ble Chief Minister, Mizoram for favour of information of hon’ble Chief Minister.
2 P.S to Speaker, Mizoram for favour of information of Speaker.
3 All P.S to Ministers, Mizoram for favour of information of the Ministers.
4 P.S to Deputy Speaker, Mizoram for favour of information of Deputy Speaker.
5 All Commissioners and Secretaries, Government of Mizoram for favour of information.
6 The Chief Engineer, PWD Zone - I & II, PWD Mizoram for favour of information
7 All Head of Departments, Government of Mizoram for favour of information.
8 All S.E, PWD for information and necessary action.
9 All E.E, PWD for information and necessary action.
10 Guard File,

Engineer in Chief
PWD, Mizoram

 

 